Technical Datasheets
Electrode Type: Silver/Silver
Chloride/Potassium Chloride (gel): pre -potted

The CP10P is manufactured as a robust reference electrode (half -cell) ideal for embedding in reinforced concrete structures. A cementitious junction removes the need for pre -potting whilst ensuring intimate contact with the concrete or repair material.

PDFView / Download PDF

Electrode Type: Silver/Silver
Chloride/Potassium Chloride (gel): bagged

The CP40 is manufactured as a robust reference electrode (halfcell) ideal for burial in soils and sand. Suitable intimate contact with the environment should be ensured by packing soil or sand around the pre-bagged electrode prior to backfilling.

PDFView / Download PDF

Electrode Type: Corrosion Potential and corrosion rate probe
CP200 – Drilled in LPR Probe

The CP200 is manufactured as a robust assembly based on the established technology and record of the CP10P silver/silver chloride half-cell. The construction is such that the half cell and associated graphite counter electrode are mounted together in an inert resin to form an integral unit allowing installation as a one step process.

PDFView / Download PDF

Electrode Type: Corrosion Potential and Corrosion Rate (LPR) Probe
CP101 - Side Entry Cabling

The CP101 is manufactured as a robust assembly based on the established technology and record of the CP10P silver/silver chloride half-cell.

PDFView / Download PDF

Corrosion Rate (LPR)
CP300 - Side Profile Probe Head

The CP300 is manufactured as a robust assembly based on the established technology and record of the CP10P silver/silver chloride half-cell.

PDFView / Download PDF

Embeddable Chloride Depth
Electrode: CP80

The CP80 is manufactured as a robust reference electrode (halfcell) ideal for embedding in new reinforced concrete structures.

PDFView / Download PDF

AchillesEDS: The Early Detection Corrosion Management System

The issue of corrosion of structures is a growing one. The problem is also global with an increasing amount of ageing stock the need to know what is happening is paramount. At a cost of 4-5% of a nation’s GDP the problem is not an inexpensive one.

PDFView / Download PDF

AchillesICP incorporating LANode® The Cathodic Protection Management System

Cathodic Protection systems today are growing as a cost-effective option for the civil, structural and building engineer faced with the task of maintaining and ensuring the durability of structures. They do however need specific management which cannot always be performed manually even by the seasoned specialist.

PDFView / Download PDF

AchillesIES: The Corrosion Inhibitor Evaluation System

Surface-applied corrosion inhibitors (SACI’s), whether embodied within the concrete mix, spray-applied as a treatment or vapour-phase form as an “emitter”, are growing as a low cost option for the civil engineering and building engineer faced with the task of maintaining and ensuring the durability of structures.

PDFView / Download PDF

Introduction to the LONWORKS® System

This document is an introduction to the basics of the LONWORKS system. It begins with an overview of networks and protocols, highlights the technical aspects of the LONWORKS protocol, provides an overview of the components of the LONWORKS system, and ends with a discussion on achieving product interoperability.

PDFView / Download PDF